Connections to ESP Breaker Panel - with single AC group
RCD
(not supplied)
0V from ESP System Panel
(allows System Panel to control backlight)
OR 0V from Boat supply
ESP AC Breaker Panel
9V from ESP System Panel
(allows System Panel to control backlight)
OR 9 - 30V from Boat supply
To 230V consumer (live)
To 230V consumer (neutral)
Neutral Busbar (not supplied)
WARNING:
The installer must ensure that the rear of the
panel and live bus bar is inaccessible once
installed.
Ensure all cables are correctly sized for the fuse
or circuit breaker protecting them.
Alternate connection
point for main supply.
Both connections can
be used.
20 A
16A
16A
10A
10A
10A
10A
10A
5A
5A
5A
Note:
Undo 2 x nuts to remove
backlight PCB to allow
fitting of Custom Window
Label
Earth Busbar (not supplied)
All supply & consumer earths to this point
To 230V consumer (earth)